Project

General

Profile

Bug #4210

Problem with ISIS2 PLANCD

Added by Mike Martin about 2 years ago. Updated about 2 years ago.

Status:
Acknowledged
Priority:
Normal
Assignee:
-
Category:
Applications
Target version:
-
Test Reviewer:

Description

I am using Trent's virtual machine ISIS2 on KDE 3.5.5 on openSUSE 10.2. The ISIS2 software version is 2.3.6, which is not an option in the menu below. When trying to run PLANCD on either Mariner 9 or Mariner 10 VSFEDR files I am getting an error "%BF2CSTR-INVSIZ - invalid string length (144805976): Bad address
IOT Trap".

PLANCD worked fine a couple years back when I was running isis2 on Ubuntu Linux with ISISVERSION = "2.3.5-REL_1_0". I tried uploading the VSFEDR file but this web page rejects the file because of it's extension.

Program Listing ------------------------------
/home/i2user> plancd from=MME_032.212 to=12327986.cub, cdid=test, mission=MARINER9

GROUP = PLANCD
ISISVERSION = "2.3.6-REL_NIGHTLY"
ISISBUILDDATE = "2013-10-28T00:08:36"
VERSION_DATE = 1998-06-05
DATE_TIME = 2016-08-08T12:40:31
NODE_NAME = "linux-ksrq"
USER_NAME = "i2user"
SOFTWARE_DESC = "Convert JPL formatted CD images to ISIS cube files"
USERNOTE = " "
GROUP = PARAMETERS
FROM = "MME_032.212"
TO = "12327986.cub"
CDID = "test"
MISSION = "MARINER9"
OTYPE = NULL

Input CD file: MME_032.212
CD Identifier: test

Output File: 12327986.cub
Image size (nl, ns): 700, 832
%BF2CSTR-INVSIZ - invalid string length (144805976): Bad address
IOT Trap
Abort
/home/i2user>

History

#1 Updated by Tammy Becker about 2 years ago

  • Status changed from New to Acknowledged

#2 Updated by Tammy Becker about 2 years ago

  • Tracker changed from Question to Bug

We have been able to reproduce the error internally.

This will require a developer to investigate the source of the problem.

This has been flagged as a "bug" and triaged internally in order to include in the que for a potential fix.

Internal test area: /work/users/tbecker/IsisTesting/M04210_plancd_Mar9/