ISIS 3 Application Documentation
clemhirescal | Standard View | TOC | Home |
Calibrate Clementine Hires images
Description
Categories
Groups
Examples
History
| Name | Description |
|---|---|
| FROM | Input cube to be calibrated |
| TO | Output of calibrated cube |
| Name | Description |
|---|---|
| KFROM | K value selection |
| KVALUE | An averaged K value |
Use this parameter to select the filename
| Type | cube |
|---|---|
| File Mode | input |
| Filter | *.cub |
This file will contain the results of the calibration
| Type | cube |
|---|---|
| File Mode | output |
| Pixel Type | real |
| Filter | *.cub |
This parameter is used to choose either a user entered K value or a previously set, calculated K value.
| Type | string | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Default | COMPUTED | |||||||||
| Option List: |
|
The K value is the absolute coefficient per wavelength and MCP gain state. This is an average of several possible K values, the default should not be used when possible as it is an average.
| Type | double |
|---|---|
| Default | 0.00125 |
| Minimum | 0.0 (exclusive) |
| Maximum | 0.05 (exclusive) |
Usage of the Clementine Hires calibration
|
clemhirescal gui
|
Example GUI Screenshot of the GUI with parameters set to calibrate a hires image using a perviously set K value. |
|
The image before the calibration
|
Input image before calibration
Parameter Name:
FROM This is the image as it was taken originally, complete with hotspot and chickenwire pattern. |
| Flat file denominator | This is one of the four avaliable flat files. It is the one used on the image you see, it is specifically for the D filter type. |
|---|
|
The image after the calibration
|
Output image after calibration
Parameter Name:
TO The image should now appear more even, without hotspot or chickenwire pattern, and radiometrically calibrated. |
| Mackenzie Boyd | 2009-08-03 | Original version |