This program calibrates LRO WAC images

Description
Categories
Groups
History


Description

This program applies dark, flat-field, radiometric, and temperature corrections for each framelet based on the band's filter number. There is also an optional mask to replace special pixels in the calibrated image. In order to output in I/F units, the cube must have spice data.

Corrections are applied in the following order: Dark, Flat-field, Radiometric, Special pixel mask, and Temperature.

Dark Correction:

If the DarkFile parameter is set, the given file(s) will be used for calibration. If DarkFile is set to "Default" or not set at all, the dark files will be looked up based on the time and temperature in the WAC being calibrated. The parameter,MiddleTemperatureFpa, is used for temperature and StartTime for time. This program, lrowaccal, will attempt to find the 2 dark files with closest time/temperature and interpolate/extrapolate from them. The method for finding dark files is as follows:

Once the dark files are found, the correction is applied:

        output[pixel] -= (dark1[pixel] - dark2[pixel])/(dark1Temp - dark2Temp)*(frameTemp-dark2Temp) + dark2[pixel]
      
where
        dark1, dark2 = dark file cubes
        dark1Temp, dark2Temp = temperature of dark1 file and dark2 file
        frameTemp = (WAC EndTemperatureFpa - WAC BeginTemperatureFpa)/WAC NumFramelets * frame + WAC BeginTemperatureFpa
      

Flat-field Correction:

        output[pixel] /= flatfield[pixel]
      
If FlatfieldFile is not set, flat-field cube is loaded from $lro/calibration/wac_flats/WAC_<wac mode>_Flatfield.????.cub

Radiometric Correction:

      output[pixel] /= WAC ExposureDuration
      if radiometricType == iof
        output[pixel] *= solarDistance2 / iofResponsivity[band]
      else
        output[pixel] /= radianceResponsivity[band]
      
where
        solarDistance is distance from the Moon to the Sun
      
If RadiometricFile is not set, radiometric responsivity is loaded from $lro/calibration/WAC_RadiometricResponsivity.????.pvl

Special Pixel Mask:

      for each framelet in the output cube
        if specialPixelMask[pixel] is special
          outputFramelet[pixel] = specialPixelMask[pixel]
      
If SpecialPixelsFile is not set, special pixel mask is loaded from $lro/calibration/wac_masks/WAC_<wac mode>_<temp>C_SpecialPixels.????.cub. temp is closest temperature to WAC MiddleTemperatureFpa.

Temperature Correction:

        for each framlet in the output cube
          if output[pixel] is special- leave it alone
          else preform the correction
        
Correction:

                inputPixel
            --------------------
             a*(frameTemp) + b

             Where:
               'a' and 'b' are band dependent constants, read in from a file.
             AND
               frameTemp = (WAC EndTemperatureFpa - WAC BeginTemperatureFpa)/WAC NumFramelets * frame + WAC BeginTemperatureFpa
      
If TEMPRATUREFILE is not set, the constants are loaded from $lro/calibration/WAC_TempratureConstants.????.pvl

The DN level in an uncalibrated image is the sum of the true signal from the scene, the bias, the dark current, and random noise in all 3 components. The random noise in the true signal and dark current is called shot noise and the random noise in the bias is called read noise. The true signal, bias, and dark current are defined as mean values so that if the random noise were averaged down to insignificance by taking a very large number of images and averaging them, the resulting image would be the true scene, bias, and dark current with no systematic error. That implies the statistical distribution of the random noise has an average of zero, and therefore the random noise has both positive and negative values, except for the trivial case of zero random noise.

The calibration equation is:

  reportedDN = ObservedDN - MeanBias - DarkCurrent 
Where:
   ObservedDN = TrueDN + E
   E is a randomly sampled value from (mu, sigma^2) and mu=0
   TrueDN is the signal that would be reported in an idealized case of an instrument with zero noise.

Let's look at the case of a calibrated image for which the true signal is zero, a dark image. In calibration the mean bias and dark current are subtracted. The random noise term is then randomly sampled from a known distribution with a mean of zero. Since the distribution has a mean of zero, values for the random noise can be positive or negative. Therefore, the addition of random noise to a pixel with true signal near zero can result in negative DN values.

Negative reported DNs are possible when E < -1 * TrueDN. These are pixels in a very dark image that happen to have a strongly negative random noise value.

Note: ObservedDN and TrueDN both must be greater than or equal to zero. For ObservedDN, it's because the hardware is not able to report negative DN values . For TrueDN, it's because radiance and reflectivity cannot be negative. The dimmest target is one that is completely dark, and for that target TrueDN = 0.

If run on a non-spiceinited cube, this program requires access to local mission-specific SPICE kernels, in order to find the distance between the sun and the target body. When run on a spiceinited cube, this can be determined using the camera model. Using a spiceinited cube as input has the advantage of not requiring that local mission-specific kernels be available. (See spiceinit web=true.)


Categories


Parameter Groups

Files

Name Description
FROM Input Image
TO Output Image

Dark Options

Name Description
Dark Calibrate using a dark file.
DarkFile Dark file used for calibration.

Flatfield Options

Name Description
Flatfield Calibrate using a flatfield file.
FlatfieldFile Flatfield file used for calibration.

Radiometric Options

Name Description
Radiometric Do radiometric calibration.
RadiometricType Calibrated output cube units.
RadiometricFile Radiometric constants file used for calibration.

Special Pixels Options

Name Description
SpecialPixels
SpecialPixelsFile This option will apply a special pixel mask to the cub. The default is to use the system defined mask file with the matching WAC mode and closest Temperature to the input cub. Please see the main documentation for a detailed description of the Special Pixel Mask correction.

Temperature Options

Name Description
Temperature Calibrate using temperature base correction.
TemperatureFile Temperature gain and offset file.

Files: FROM

Description

This is the non-calibrated, unprojected WAC cube

Type cube
File Mode input
Filter *.cub

Files: TO

Description

This is the calibrated WAC cube

Type cube
File Mode output
Pixel Type real
Filter *.cub

Dark Options: Dark

Description

Calibrate using a correction based off of a dark file. Please see the Dark Correction section at the beginning of this document for a detailed explanation of how the correction is applied

Type boolean
Default True
Inclusions
  • DarkFile

Dark Options: DarkFile

Description

Dark file used for calibration. The default is to use the dark file with the closest time and temperature to the WAC image being calibrated. See the Dark Correction section at the beginning of this document for a detailed explanation of how dark files are chosen.

Type filename
Default Default

Flatfield Options: Flatfield

Description

Calibrate using a flatfield file.

Type boolean
Default True
Inclusions
  • FlatfieldFile

Flatfield Options: FlatfieldFile

Description

Flatfield file used for calibration. The default is to use the system defined dark file with the highest version number.

Type filename
Default Default

Radiometric Options: Radiometric

Description

Perform a radiometric calibration on the input cub. This type of this correction is defined by the RadiometricType parameter.

Type boolean
Default True
Inclusions
  • RadiometricType
  • RadiometricFile

Radiometric Options: RadiometricType

Description

Calibrated output cube units. I/F or radiance.

Type string
Default IOF
Option List:
Option Brief Description
IOFI/F
RADIANCERadiance

Radiometric Options: RadiometricFile

Description

Radiometric constants file used for calibration. The default is to use the system defined file with the highest version.

Type filename
Default Default

Special Pixels Options: SpecialPixels

Description

This option will apply a special pixel mask to the input cub. The default is to use the system defined mask file with the matching WAC mode and closest Temperature to the input cub. Please see the main documentation for a detailed description of the Special Pixel Mask correction.

Type boolean
Default True
Inclusions
  • SpecialPixelsFile

Special Pixels Options: SpecialPixelsFile

Description

Type filename
Default Default

Temperature Options: Temperature

Description

Calibrate using temperature gain and offset. Please see this document, which outlines how the correction was derived.

Type boolean
Default True
Inclusions
  • TemperatureFile

Temperature Options: TemperatureFile

Description

Temperature gain and offset file. The default is to use the system defined temperature gain and offset file with the highest version number.

Type filename
Default Default

History

Jacob Danton2009-07-01 Original version
Dan Clarke2012-08-13 Updated use of deprecated methods (use ProcessCube instead of Start/EndProcess). Updated documentation/comments. Optimized/cleaned up code in Calibrate, GetDark, and GetMask. Changed the algorithm for finding dark files in GetDark. GetDark will now find the two closest available dark file temperatures matching the input WAC cube. Then, it will find the dark file at each temperature with the time closest to the WAC time. This should prevent failed calibrations from missing darks.
Adam Licht2012-12-18 Fixed an error which would apply band 1 corrections to a single passed in band, even if that band was not band 1.
Adam Licht2013-04-16 Implemented a temperature based correction to lrowaccal. This correction requires constants which are read from a pvl file. A file other than the default can be passed in via an argument. The correction may also be turned off via an argument.
Stuart Sides2021-02-22 Added ability to get the sun distance from the camera.
Cordell Michaud2022-05-03 Refactored lrowaccal to be callable for testing and to remove global variables and helper functions. Added units label "W/m2/sr/um" to RadiometricType keyword in output cube label when RadiometricType is AbsoluteRadiance.