ISIS Application Documentation
    Remove frame transfer smear
  
 
          Description
        
    This program removes the frame transfer smear from a CCD
    camera.  Transfer smear is the build up of residual enegy as the data is read 
    from the detector, line by line.  The current algorithm is written to remove smear for a
    CCD that reads data at the top of the detector.  No visual examples have
    been included because, the difference between the input and output is only a
    few DN values.
   
 
          Categories
        
 
              History
          
| Tracie Sucharski | 2003-06-16 | 
      Original version,  algorithm from Andrew E. Johnson
      (aej@robotics.jpl.nasa.gov).
     | 
 
| Bob Sucharski | 2005-11-04 | 
      Converted to Isis 3.0
     | 
 
| Brendan George | 2006-09-28 | 
        Documentation fixes
     | 
 
| Steven Lambright | 2008-05-13 | 
      Removed references to CubeInfo 
     | 
 
 
 | 
 
 
                Parameter Groups
            
Files
| 
                    Name
                     | 
                    Description
                     | 
 
| FROM | 
          Input file to be corrected
         | 
 
| TO | 
          Output cube
         | 
 
 
Correction Values
| 
                    Name
                     | 
                    Description
                     | 
 
| DURATION | Exposure duration of input file. | 
 
| TRANSFER | Frame transfer time | 
 
 
 | 
 
Files:
                        FROM
                         Description
                       
          The input cube that will be corrected for CCD smear.
        
| 
                             Type
                            | cube | 
| 
                               File Mode
                              | input | 
| 
                               Filter
                              | 
          *.cub *.lbl
         | 
 
 
Files:
                        TO
                         Description
                       
          The smear corrected output cube
        
| 
                             Type
                            | cube | 
| 
                               File Mode
                              | output | 
| 
                               Pixel Type
                              | real | 
| 
                               Filter
                              | 
          *.cub
         | 
 
 
Correction Values:
                        DURATION
                         Description
                       
                  The exposure duration value to be used in the smear calculation.
                  Exposure duration is the value of time between the opening and closing
                  of a instrument aperture.
                  If NO value is entered by the user, the value will be filled
                  with the exposure duration keyword from the Instrument group
                  The exposure duration value must be in the same units as the transfer time.
        
| 
                             Type
                            | double | 
| 
                               Internal Default
                              | 
          From labels
         | 
 
 
Correction Values:
                        TRANSFER
                         Description
                       
                  Time required to transfer data from from active imaging area.
                  If NO value is entered by the user, the value will be filled 
                  with the transfer time keyword from the Instrument group.
                  The transfer time value must be in the same units as the exposure duration
        
| 
                             Type
                            | double | 
| 
                               Internal Default
                              | 
          From labels
         |