ISIS Application Documentation
    Import MESSENGER/MDIS EDR/RDR products into ISIS cubes
  
 
          Description
        
    
      This program, mdis2isis, converts PDS-labelled Mercury Dual Imaging (MDIS)
      Experiment Data Records (EDRs) or Reduced Data Records (RDR) to ISIS labels.
      MDIS has a narrow angle camera (NAC) and a wide angle camera (WAC)
      with twelve filters. These observations, using mdis2isis, are converted to
      ISIS format, and the resulting ISIS cubes are ready for SPICE initialization and projection.
     
    
      Some MDIS-images are compressed onboard the spacecraft.  When such
      compression is detected by mdis2isis, each DN is converted to its
      pre-compressed, 12-bit DN value using the original Lookup Table (LUT).
      All output files are created in floating point DN format.
     
    
      There are DN limits that are imposed on the output pixel.  For the NAC
      instrument, the valid range is 0 < DN < 3400.  The limit for the WAC
      is 0 < DN < 3600.  For both instruments, 0 values are mapped to the
      NULL special pixel value.  Values that exceed the maximum are set to
      the HIS (high instrument saturation) special pixel value.
     
   
 
          Categories
        
 
              History
          
| Kris Becker | 2005-07-25 | 
      Original version
     | 
 
| Elizabeth Miller | 2005-11-15 | 
        Added appTest
     | 
 
| Steven Lambright | 2007-12-10 | 
        Added Lookup Table capabilities
     | 
 
| Steven Lambright | 2007-12-11 | 
        Fixed problem where labels went outside the IsisCube object
     | 
 
| Kris Becker | 2008-01-19 | 
        Added validation of filter number here.  The number in the label is
        unreliable and requires validation as filter identification is critical
        in calibration and camera model (at a minimum).    If it cannot be
        determined, the number is set to "Unknown" which renders the file
        unusable for calibration and geometric operations.
     | 
 
| Christopher Austin | 2008-03-18 | 
      Checks if input file is rdr.
     | 
 
| Steven Lambright | 2008-05-13 | 
      Removed references to CubeInfo
     | 
 
| Kris Becker | 2008-09-03 | 
       Reworked the lut inversion implementation to use a different dn table
       source.  This altered the resulting DNs a bit.  Also instituted DN limits
       for low (0) and high saturation levels for WAC (3600) and NAC (3400).  DN
       values that exceed these maximums are set to NULL and HIS (High
       Instrument Saturation), respectively.  Started the SOURCE_PRODUCT_ID
       pedigree  chain.
     | 
 
| Steven Lambright | 2009-12-29 | 
      Now looking for mdisCalibration????.trn in $messenger/calibration instead of
      $messenger/translations
     | 
 
| Kris Becker | 2011-06-15 | 
        Added YearDoy keyword to the Archive group. The format is a valid
        numerical value.  This value is created from the StartTime,
        multiplying the year by 1000 and adding the day-of-year ; added the
        OrbitNumber keyword to the translation tables for inclusion in the
        Archive group.
     | 
 
| Kaitlyn Lee | 2018-01-17 | 
        Reworded application description to make it more understandable.
     | 
 
 
 | 
 
 
                Parameter Groups
            
Files
| 
                    Name
                     | 
                    Description
                     | 
 
| FROM | 
          Input cube file name
         | 
 
| TO | 
          Output cube
         | 
 
 
Parameters
| 
                    Name
                     | 
                    Description
                     | 
 
| TARGET | Provide observation target if not in EDR | 
 
| UNLUT | 
          Convert 8-bit values to 12-bit values
         | 
 
 
 | 
 
Files:
                        FROM
                         Description
                       
          The input MDIS EDR/RDR file
        
| 
                             Type
                            | filename | 
| 
                               File Mode
                              | input | 
| 
                               Filter
                              | 
          *.IMG *.IMA
         | 
 
 
Files:
                        TO
                         Description
                       
          Output file converted from PDS EDR format to ISIS.  This ISIS file will have all the
          information transferred from the PDS EDR file that is necessary to
          initialize for geometric processing (see spiceinit, cam2map, etc).
        
| 
                             Type
                            | cube | 
| 
                               File Mode
                              | output | 
| 
                               Pixel Type
                              | real | 
| 
                               Filter
                              | 
          *.cub
         | 
 
 
Parameters:
                        TARGET
                         Description
                       
                This parameter may be necessary as some EDR labels do not adequately define
                the TARGET_NAME keyword in the labels.  Messenger takes a very long trip to
                finally arrive at Mercury orbit in 2011.  During cruise, many flybys occur.  The
                proper specification of the TARGET_NAME is critical to valid instantiation of
                ISIS camera models.
                When this application was originally written, NULL was a frequently
                occurring value of the TARGET_NAME keyword even for flyby encounters.
                This keyword allows one to specify the observed body,
                as many flybys occurred, explicitly for these cases.
                The default is to honor the value in the EDR label as it is anticipated this will be
                corrected in subsequent EDR generation.
            
| 
                             Type
                            | string | 
| 
                               Internal Default
                              | Label Value | 
 
 
Parameters:
                        UNLUT
                         Description
                       
          If this is set to true, and the input cube is lutted, a Lookup Table
          will be used to convert the original DN values to their original
          12-bit values. This must be set to true for calibration.
        
| 
                             Type
                            | boolean | 
| 
                               Default
                              | 
          
            true
          
         |