DescriptionThis program will create a control network by combining control points from one or more control networks into single points that satisfy image distance criteria. It employs a more robust/direct technique than cnetmerge. This technique evaluates each control point in all input networks by finding all candidate merger control points who have a measure within IMAGETOL. Then, for each candidate point, the average distance of the measures in the candidate to a measure in the source point is computed. If the average distance to any measure in the source point is less than IMAGETOL, then the candidate point and source point are merged. The candidate control point is disabled so that it will never be considered for another merger and the now augmented control point is added back to the search pool for further merger considerations, which can occur when other common measures are considered. When all control points have been searched and all mergers have taken place, a new single combined control network is created. Note that this application can be ran more than once and directly on the output of any past run (in other words, you need only provide a single network, if desired). CategoriesRelated Objects and DocumentsApplicationsHistory
|
Parameter GroupsInput
Output
Parameters
|
The base control network file to which others will be matched.
Type | filename |
---|---|
File Mode | input |
Internal Default | None |
Filter | *.net *.cnet *.ctl |
A control network that will be matched to the base (i.e. master) network.
Type | filename |
---|---|
File Mode | input |
Internal Default | None |
Filter | *.net *.cnet *.ctl |
A list of control network file names that will be matched to the base (i.e. master) network.
Type | filename |
---|---|
File Mode | input |
Internal Default | None |
Filter | *.lis *.txt |
The output Control Network, which is the combined result of the input networks.
Type | filename |
---|---|
File Mode | output |
Internal Default | None |
Filter | *.net *.cnet *.ctl |
Provided with a filename in this option, all the cube serial numbers that are contained in the network are written to this file as soon as it is determined in the processing.
Type | filename |
---|---|
File Mode | output |
Internal Default | None |
Filter | *.lis |
The NetworkId keyword for the newly merged ControlNet will be set to this given value. The Networkid is a single word identifier or name assigned to a Control Network.
Type | string |
---|---|
Internal Default | None |
The Description keyword for the newly merged ControlNet will be set to this given value. This should be a brief description of the purpose of the merged control network.
Type | string |
---|---|
Internal Default | None |
A four column CSV file that contains which input control points were merged into output control points. The first column contains the ID of each output control point that had at least one input control point merged into it. The second column contains the number of measures in the input control point. The third column contains the number of measures in the output control point. The fourth column contains a space separated list of the IDs of input control points that were merged into the output control point.
Type | filename |
---|---|
Internal Default | None |
The acceptable distance, in pixels, for merging points.
Type | double |
---|---|
Default | 1.0 |
Number of leaves in the kd-tree structure.
Type | integer |
---|---|
Default | 10 |
When TRUE, all points apriori latitude/longitude surface point is updated to use the best one available. This is often the resulting coordinate after jigsaw has adjusted the surface point.
Type | boolean |
---|---|
Default | false |
When true, all invalid or ignored control points and measures are removed from the output control network as one of the main objectives of this application is to remove redundancies and mimimize the size of networks. However, for evaluation purposes, you can set this to false, which will preserve all control points.
When specifying the minimum number of measures/control point using the MINMEASURES parameter, any control point that does not meet this criteria will also be removed from the netwrk when CLEANNET=true, otherwise these points will be set to ignored.
Type | boolean |
---|---|
Default | true |
When true, all invalid or ignored control points and measures are removed from the output control network as one of the main objectives of this application is to remove redundancies and mimimize the size of networks. However, for evaluation purposes, you can set this to false, which will preserve all control points.
When specifying the minimum number of measures/control point using the MINMEASURES parameter, any control point that does not meet this criteria will also be removed from the netwrk when CLEANNET=true, otherwise these points will be set to ignored.
Type | boolean |
---|---|
Default | true |
This allows users to disable points that have less than MINMEASURES control measures/control point. For example, if you want to flag all points as ignored with 2 measures or less, set MINMEASURES=3. Points that don't meet this critieria are set to ignore and are subject to the CLEANNET action requested by the user (i.e., all ignored points are removed from the network if CLEANNET=true).
Type | integer |
---|---|
Default | 0 |